Code: C0350 kyocera Taskalfa 5052ci

//Code: C0350 kyocera Taskalfa 5052ci

Code:C0350


Issue:

Panel PWB communication error (Electronic volume I2C communication error)


Solution:

  • Reset Main Power for Operation Panel Issue
    • Problem: Operation panel main PWB malfunction.
    • Solution: Turn off both power switches, wait 5 seconds, then turn them back on.
  • Check Wire Connections
    • Problem: Wire improperly connected to operation panel main PWB.
    • Solution: Reinsert wire connectors from Operation panel PWB to Main PWB and NFC PWB.
  • Replace Faulty Wire
    • Problem: Faulty wire connected to operation panel main PWB.
    • Solution: Replace broken, short-circuited, or grounded wires between Operation main PWB, Main PWB, and NFC PWB.
  • Replace Operation Panel Main PWB
    • Problem: Faulty operation panel main PWB detected.
    • Solution: Replace the operation panel main PWB.
  • Replace Faulty Main PWB
    • Problem: Main PWB malfunction.
    • Solution: Replace the main PWB.
  • Replace NFC PWB
    • Problem: Faulty NFC PWB detected.
    • Solution: Replace the NFC PWB.