Code: C0160 kyocera Taskalfa 5052ci

//Code: C0160 kyocera Taskalfa 5052ci

Code:C0160


Issue:

The data read from the EEPROM is judged as abnormal.


Solution:

  • Reset Main Power for EEPROM Issue
    • Problem: Engine PWB’s EEPROM malfunction.
    • Solution: Turn off both power switches, wait 5 seconds, then turn them back on.
  • Execute U021 to Rectify Faulty Storage Data
    • Problem: Faulty storage data detected in the EEPROM on the engine PWB.
    • Solution: Execute U021 to address the issue.
  • Replace Faulty EEPROM
    • Problem: Faulty EEPROM identified on the engine PWB.
    • Solution: Replace the defective EEPROM on the engine PWB and execute U004 for proper functionality.